6-in-1 Power System (Oilman Series)

For industrial jobsites with flammable gasses present, there is no better system.

The VMAC Multifunction Oilman series includes everything you need for safe operations on any jobsite in a single compact system. This self-contained system can be fully integrated into any diesel work truck fuel system or skid-mounted for stand-alone applications with an optional external fuel tank.

Why is a Positive Air Shutoff System (PASS) required?

A Positive Air Shutoff System is a necessity for anyone with a diesel engine that may come in contact with natural gas, propane, or any other flammable gasses. A small leak of flammable gas is likely to cause a diesel engine to “run away”, causing catastrophic damage to the engine, and surrounding area as it explodes.

A diesel engine will utilize any fuel available, and flammable gas in the air is more than enough to keep a diesel engine running, even when the key is removed. Once a diesel engine gets a supply of flammable gas from the air, it will run indefinitely or to the point of catastrophic failure. The only way to prevent and stop this is to shut off the air supply to the engine, starving it of fuel.

The Shocker PASS® senses high-revving “runaway” situations and will automatically shut the intake valve, choking off the air supply to protect the engine, as well as property and personnel in the area.

Components included:

  • Shocker PASS® Positive Air Shutoff System
  • 45 CFM Rotary Screw Air Compressor
  • 8 kW AC Generator
  • 250 A DC Welder (adjustable)
  • 300 A max @ 13V Booster (adjustable) 
  • 100 A max @ 12V, 24V Battery Charger (adjustable)
  • 2,800 RPM Power Take-off Port
  • 5 GPM, 8 GPM, or 10 GPM @ 3,500 psi (max) Hydraulic Pump
  • Factory-installed Cold Climate Kit – 120V, tested to -40°F (-40°C)

Applications – Common jobs that use 6-In-1 Power Systems:

  • Industrial jobsites with flammable gases present
  • Oil & gas leases
  • Mobile heavy duty mechanics
  • Heavy equipment repair technicians
  • Remote access jobs in mining, logging and oil & gas

6-in-1 Power System - Oilman Series Benefits

Free Up Space

VMAC Multifunction Power Systems leave more space on your truck deck or cargo area because they combine multiple functions into one compact system. The overall system size is six cubic feet smaller than other leading multi-power brands and designed to fit on the side pack of a service truck with a slider.

Reduce Weight

VMAC’s Multifunction reduces truck GVW by 140 lb. Choosing a lightweight multi-power system means you’ll be able to add more tools and equipment to your truck, carry more materials, take advantage of better fuel economy, or even downsize your truck classification.

Reduce Truck Maintenance & Fuel Costs

Multifunction Power Systems reduce truck maintenance costs and improve fuel economy by allowing you to turn your truck engine off while on the job site. The control system not only automatically idles the system’s engine up/down with air demand, it also turns the engine off/on with air demand.

Easy To Operate & Switch Between Systems

VMAC Multifunction Power Systems allow you to seamlessly switch between operations, without the hassle of complicated controls or maneuvering multiple machines on the job site. This means more time working, improving productivity, and getting your customers back to work faster. It is designed for ease-of-use, to run efficiently with only one operator.

Includes Shocker PASS® (Positive Air Shutoff System)

The Shocker PASS® senses high-revving “runaway” situations and will automatically shut the intake valve, choking off the air supply to protect the engine, as well as property and personnel in the area.

6-in-1 Power System - Oilman Series Components

Air Compressor

Oil-injected rotary screw; belt-driven; 45 CFM @ 100 psi, 100% duty cycle; up to 175 psi

AC/DC Generator/Welder/Battery Charger/Booster
  • AC: 8 kW output (w/ terminal strip)
    • 1 x 30 A, 240V, 60 Hz three phase circuit
    • 2 x 20 A, 120V, 60 Hz single phase circuit

  • DC: For battery boosting/charging; other DC loads
    • Boost – 300 A max @ 13V; Charge – 100 A max @ 12V, 24V
    • CC mode for SMAW and GTAW (stick/TIG welding)
    • 250 A @ 35% duty cycle; 190 A @ 60% duty cycle
Generator/Welder Control Box

GENSET voltage meter & selector; welding current control and ARC force; socket for optional remote welding control

Cat C1.1 Industrial Diesel Engine

Tier 4 Final; inline 3, 4-stroke naturally aspirated (extended oil change interval 500 hrs/1 yr)

PTO Port

Clutched SAE ‘A’ port with 9-toothed spline, 2,800 RPM output; 35 lb-ft continuous torque max (patented)

Hydraulic Pump

5 GPM, 8 GPM, or 10 GPM @ 3,500 psi (max)

Control/Digital Display Box

Remoted mounted; electronic key switch; selector switches for PTO/GENSET/COMPRESSOR; LCD for compressor on/off controls, observing system status and adjusting parameters

Battery

Included ACDelco 12V, 460 CCA, 575 CA

Air/Oil Separator Tank

Separates compressor oil from compressed air

Positive Air Shutoff System (PASS)

Shocker PASS® automatically senses high-revving engines situations and closes the air supply to the engine

Cold Climate Kit For -40º

Cold Climate Kit is recommended if ambient temperatures frequently drop below -10ºC (14ºF); combine with an optional 1,750 W inverter to warm the system on the way to the job site

6-in-1 Power System - Oilman Series Specifications

Air Compressor
  • 45 CFM @ 100 psi (175 psi max)
  • VMAC oil-injected rotary screw; 100% duty cycle; belt-driven
Engine
  • Cat C1.1 industrial diesel engine
    • Inline 3, 4-stroke, naturally aspirated, 3,400 RPM, Tier 4 Final
Weight (wet)
  • Approximately 710 lb (322 kg)
Dimensions
  • 34.8” (l) x 24.8” (w)* x 31.3” (h); 88.4 cm (l) x 63 cm (w) x 79.5 cm (h)
  • Base footprint: 34.5” (l) x 19.5” (w); 87.6 cm (l) x 49.5 cm (w)
  • *29.75” (75.6 cm) w/ radiator sound deflector
Decibels (dB) @ 21 feet (6.4 meters)
  • 74.25 dB at high idle, 69.75 dB at low idle, 0 dB in Standby Mode
AC/DC Generator/Welder
  • AC: 8 kW output (w/ terminal strip)
    • 1 x 30 A, 240V, 60 Hz three phase circuit 
    • 2 x 20 A, 120V, 60 Hz single phase circuit
  • DC: For battery boosting/charging; other DC loads
    • Boost – 300 A max @ 13V; Charge – 100 A max @ 12V, 24V
    • CC mode for SMAW and GTAW (stick/TIG welding)
    • 250 A @ 35% duty cycle; 190 A @ 60% duty cycle
Power Take-off Port
  • Clutched SAE ‘A’ port with 9-toothed spline, 2,800 RPM output, 35 lb-ft continuous torque max (patented)
Hydraulic Pump
  • 5 GPM, 8 GPM, or 10 GPM @ 3,500 psi (max)
Battery
  • ACDelco 12V, 460 CCA, 575 CA
Control System
  • Remote mounted control/digital display box with electronic key switch and LCD for compressor on/off controls, observing system status, and adjusting parameters
  • Remote mounted generator/welder control box with genset voltage meter and selector, welding current and ARC force control
  • Socket for optional remote welding control
  • Integrated voltage sensing interlock feature ensures safe welding/battery boosting and protects equipment by disabling the genset in unsafe conditions
  • Separate selector switches engage compressor, generator and PTO; any function or all three can be selected at any time
  • Multi-speed throttle control responds to operating function and air demand
  • With compressor-only selected, and sustained periods of no air use, the control system will shut down the engine (Standby Mode); the engine will not shut down automatically with generator selected
Cold Climate Protection
  • Cold climate kit for ambient temperatures below -10°C (14°F)
    • Optional 1,750 W power inverter allows cold climate kit to engage on the way to the job site
  • Engine and compressor wait until the system temperatures are above 41°F (5°C) before loading and going into a running state
  •  Engine automatically restarts when system temperature falls below 23°F (-5°C)
  • Small heat strip included in LCD Digital Control Box
  • Battery jump start connections are recommended to be tied into the truck batteries in locations where extreme cold is expected; it is not necessary in mild climates
Positive Air Shutoff System (PASS)
  • Shocker PASS® automatically senses high-revving engines situations and closes the air supply to the engine
Fuel Supply Options
  • 7-gallon tank with fuel gauge and low fuel shut-off sensor
  • External Diesel Fuel Pump Kit
Air Receiver Tank
  • Minimum 10-gallon air receiver tank recommended (not included) for proper operation of all functions
Warranty
  • Two years on all major components; VMAC air ends are covered by VMAC’s Lifetime Warranty (Limited)
  • Cat engine covered by Caterpillar’s 2-year Limited Warranty
  • For more information about VMAC’s warranty policies, visit www.vmacair.com/warranty

6-in-1 Power System - Oilman Series Downloads

Accessories and Service Kits

 

Request A Quote